Impervious | Drive TEP/TXP.IP65
Corrosion free, splash-water and dust-proof - ideal for use in a humid or aggressive climate. |
| |
|
SPESIFICATIONS : |
|
| |
Application |
| Rough operating conditions : |
| • |
Industry |
| • |
Mountain railways and cable cars |
| • |
Refrigerating chambers |
| • |
Refineries |
| • |
Garages |
| High requirements in terms of the hygiene : |
| • |
Kitchens |
| • |
Bakeries |
| • |
Slaughterhouses |
| • |
Butcheries |
| • |
Zoological gardens |
| • |
Saunas |
| High requirements relating to corrosionresistance : |
| • |
All kinds of ships |
| • |
Buildings in sea proximity |
| • |
Drilling platforms |
| • |
Swimming pools |
|
| |
Standart Functions |
| • |
Self-learning processor based control system with automatic collection of system-specific data |
| • |
Continuous operating diagnosis |
| • |
Interface RS 232 |
| • |
Recognition of obstacles in opening/closing direction with safety hold-open time and sensing run |
| • |
9 freely programmable inputs |
| • |
6 freely programmable outputs |
| |
Connection facility for 4 activators and 2 safety light beams |
| |
Emergency opening/closing facilities |
| |
5 operating modes |
|
| |
Accessories/Options |
| • |
TORMAX 5 positions control panel in IP44 |
| • |
Surface mounted box with transparent cover for operating unit in IP55 |
| • |
Impulse, presence and safety sensors |
| • |
Mechanical emergency opening facility |
| • |
Battery backup system (not integrated in the drive unit) |
| • |
Independent network with TORMAX UNINET for controlling and monitoring your system |
|
| |
Standarts |
| • |
CE conformity |
| • |
Protection IP65 according to IEC 529 |
| • |
UL and cUL |
| • |
Manufactured according to ISO 9001 |
|
| TEP.IP65 |
Door leaf weight max. |
< 1 × 120 kg (1 leaf)
< 2 × 100 kg (2 leaves) |
| |
Opening speed |
30 – 80 cm / s (1 leaf)
60 – 160 cm / s (2 leaves) |
| |
Mains supply |
115 V AC / 60 Hz or 230 V AC / 50 Hz |
| |
Nominal power max. |
160 VA |
| |
Torque |
≤ 150N |
| TXP.IP65 |
Door leaf weight max. |
< 1 × 240 kg (1 leaf)
< 2 × 200 kg (2 leaves) |
| |
Opening speed |
30 – 80 cm / s (1 leaf)
60 – 160 cm / s (2 leaves) |
| |
Mains supply |
115 V AC / 60 Hz or 230 V AC / 50 Hz |
| |
Nominal power max. |
250 VA |
| |
Torque |
≤ 300N |
| |

CROSS SECTION |
| |
|